Brand Name : Cummins Power
Model Number : FM800kw
Place of Origin : CHINA
MOQ : 1
Price : Negotiable
Payment Terms : T/T
Supply Ability : 1000
Packaging Details : Plywood Package
Certification : ISO9001
Air Compressor : Integrated
Air Intake System : Turbocharged
Alternator : Brushless
Coolant Filter : Full-Flow
Cooling System : Liquid-Cooled
Emissions Compliance : EPA Tier 4 Final/EU Stage IV
Engine Type : Diesel
Exhaust System : Aftertreatment
Fuel Filter : Dual-Stage
Fuel System : High-Pressure Common Rail
Governor System : Electronic
Lubrication System : Full-Flow
Oil Filter : Full-Flow
Power Output : Up to 2000 kW
Starting System : Electric
Helpful tips on Generator Set Fault | |||
When fault occurs during generator set running,could do primary judgement according to following tips. | |||
Icon | Indicator Light | Reason | Fault Analysis and Solve Method |
High Water Temperature Alarm | High Water Temperature Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately. |
Low Oil Pressure Alarm | Low Oil Pressure Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately. |
Low Fuel Level Alarm | Low Fuel Level Alarm | When Fuel level has been detected by sensor fitted to the daily tank,the light is off. | Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately. |
Battery Charger Fault Alarm | Battery Charger Fault Alarm | The Charing System has fault while engine still running,the light is off. | Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit. |
Crank Failure Alarm | Crank Failure Alarm | When Generator set fail three times(or six times) in arow starting,the light is on | It is caused by Oil Supply System or Re-Start System Failure. |
Overload or Breaker Tripping Alarm | Overload or Breaker Tripping Alarm | When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. | For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker. |
![]() |